ORA SYSTEM® HOW-TO VIDEOS

For a quick refresher pertaining to specific aspects of the ORA SYSTEM®, click on the videos below.  

HOW-TO VIDEOS

  • ORA SYSTEM<sup>®</sup> - 1: Creating a New Patient in the Alcon<sup>®</sup> ORA SYSTEM<sup>®</sup> AnalyzOR™  Software

    ORA SYSTEM® - 1: Creating a New Patient in the Alcon® ORA SYSTEM® AnalyzOR™  Software

  • ORA SYSTEM<sup>®</sup> - 2:  Aberrometer Verification in the Alcon<sup>®</sup> ORA SYSTEM<sup>®</sup> AnalyzOR™  Software

    ORA SYSTEM® - 2:  Aberrometer Verification in the Alcon® ORA SYSTEM® AnalyzOR™  Software

  • ORA SYSTEM<sup>®</sup> - 3: Starting a Surgical Case in the Alcon<sup>®</sup> ORA SYSTEM<sup>®</sup> AnalyzOR™ Software

    ORA SYSTEM® - 3: Starting a Surgical Case in the Alcon® ORA SYSTEM® AnalyzOR™ Software

  • ORA SYSTEM<sup>®</sup> - 4: The Measurement Process with the Alcon<sup>®</sup> ORA SYSTEM® System

    ORA SYSTEM® - 4: The Measurement Process with the Alcon® ORA SYSTEM® System

  • ORA SYSTEM<sup>®</sup> - 5: Aphakic Calculation in the Alcon<sup>®</sup> ORA SYSTEM<sup>®</sup> AnalyzOR™ Software

    ORA SYSTEM® - 5: Aphakic Calculation in the Alcon® ORA SYSTEM® AnalyzOR™ Software

  • ORA SYSTEM<sup>®</sup> - 6: Pseudophakic Calculation in the Alcon<sup>®</sup> ORA SYSTEM<sup>®</sup> AnalyzOR™ Software

    ORA SYSTEM® - 6: Pseudophakic Calculation in the Alcon® ORA SYSTEM® AnalyzOR™ Software

  • ORA SYSTEM<sup>®</sup> - 7: Reviewing Measurement Images in the Alcon<sup>®</sup> ORA SYSTEM<sup>®</sup> AnalyzOR™ Software

    ORA SYSTEM® - 7: Reviewing Measurement Images in the Alcon® ORA SYSTEM® AnalyzOR™ Software

  • ORA SYSTEM<sup>®</sup> - 8: Ending a Case in the Alcon<sup>®</sup> ORA SYSTEM<sup>®</sup> AnalyzOR™ Software

    ORA SYSTEM® - 8: Ending a Case in the Alcon® ORA SYSTEM® AnalyzOR™ Software

  • ORA SYSTEM<sup>®</sup> - 9: Approving Surgeon Specific Optimized Surgeon Factors in the Alcon<sup>®</sup> ORA SYSTEM<sup>®</sup> AnalyzOR™ Software

    ORA SYSTEM® - 9: Approving Surgeon Specific Optimized Surgeon Factors in the Alcon® ORA SYSTEM® AnalyzOR™ Software

  • ORA SYSTEM<sup>®</sup> - 10: Entering Post-Operative Data in the Alcon<sup>®</sup> ORA SYSTEM® AnalyzOR™ Software

    ORA SYSTEM® - 10: Entering Post-Operative Data in the Alcon® ORA SYSTEM® AnalyzOR™ Software

Click on a product to access the video library for that product.

These videos are approved for use in the United States.

LENSX® LASER
SYSTEM

View Videos

VERIONTM IMAGE
GUIDED SYSTEM

View Videos

WAVELIGHT®
PORTFOLIO

View Videos

VIEW IMPORTANT PRODUCT INFORMATION FOR:

ORA™ SYSTEM WITH VERIFEYE+™ TECHNOLOGY IMPORTANT PRODUCT INFORMATION

CAUTION: Federal (USA) law restricts this device to sale by, or on the order of, a physician.

INTENDED USE: The ORA™ System uses wavefront aberrometry data in the measurement and analysis of the refractive power of the eye (i.e., sphere, cylinder and axis measurements) to support cataract surgical procedures.

CONTRAINDICATIONS: The ORA™ System is contraindicated for patients: 

  • who have progressive retinal pathology such as diabetic retinopathy, macular degeneration or any other pathology that the physician deems would interfere with patient fixation;
  • who have corneal pathology such as Fuchs’, EBMD, keratoconus, advanced pterygium impairing the cornea or any other pathology that the physician deems would interfere with the measurement process;
  • whose preoperative regimen includes residual viscous substances left on the corneal surface such as lidocaine gel or viscoelastics;
  • with visually significant media opacity (such as prominent floaters or asteroid hyalosis) what will either limit or prohibit the measurement process; or
  • who have received retro or peribulbar block or any other treatment that impairs their ability to visualize the fixation light.

In addition, utilization of iris hooks during an ORA™ System image capture is contraindicated, because the use of iris hooks will yield inaccurate measurements.

WARNINGS AND PRECAUTIONS:

  • Significant central corneal irregularities resulting in higher order aberrations might yield inaccurate refractive measurements.
  • Post refractive keratectomy eyes might yield inaccurate refractive measurement.
  • The safety and effectiveness of using the data from the ORA™ System have not been established for determining treatments involving higher order aberrations of the eye such as coma and spherical aberrations.
  • The ORA™ System is intended for use by qualified health personnel only.
  • Improper use of this device may result in exposure to dangerous voltage or hazardous laser-like radiation exposure.
  • Do not operate the ORA™ System in the presence of flammable anesthetics or volatile solvents such as alcohol or benzene, or in locations that present an explosion hazard.

ATTENTION: Refer to the ORA™ System Operator’s Manual for a complete description of proper use and maintenance of the ORA™ System, as well as a complete list of contraindications, warnings and precautions.