SURGICAL EXPERIENCE

Redefining the standard of performance with intuitive controls and agile hardware for an optimized experience.

LOG IN TO ORDER

Use your Online Ordering ID to access your account.

Learn more.

INTERACTIVE FEATURES ALLOW FLEXIBILITY

The culmination of thousands of collaborative research hours with surgeons and OR staff, the Centurion® Vision System delivers cutting-edge performance through a series of design innovations.

With proprietary features designed to improve patient outcomes, enhance surgical control and provide a smoother procedure overall, refractive cataract surgery will never be the same.

Centurion® Vision System Features

Every feature of the Centurion® Vision System has been purposefully placed to optimize performance.

Key Features

  • Graphic user interface (GUI):
    • - Displays essential data at all times
    • - Easy access to adjustable parameters for efficient customization
  • Wireless remote: Allows technicians the ability to control the machine from different areas within the OR. Snap focus keys interact with the GUI.
  • HD Monitor: 17-inch adjustable touch screen interface allows for easy visibility from within the OR.
  • Adjustable tray: Neutral setup provides accessibility for OD/OS procedures.
  • Rotating work surface: For easy surgical flexibility. 
  • Task light: Provides convenient illumination whenever it’s needed during the procedure.
  • Wheels: Three-inch wheels with locking casters provide cord protection and easy OR setup.
  • Foot handle: Allows surgeons and techs the ability to easily move the machine after scrubbing in.

ACTIVE FLUIDICS™

ACTIVE FLUIDICS™

Optimizing chamber stability and
surgeon control through dynamic
IOP management1-3

CENTURION® ENERGY DELIVERY

CENTURION® ENERGY DELIVERY

Harmonizing OZil® Torsional Phaco
delivery with increased fluidic control
to maximize performance4

  1. Nicoli CM, Dimalanta R, Miller K. Experimental anterior chamber maintenance in active versus passive phacoemulsification fluidics systems. J Cataract Refract Surg. 2016;42(1):157-162.
  2. Rowen S. Microincision cataract surgery. Presented January 2014; Park City, UT.
  3. Boukhny M, Sorensen G, Gordon R. A novel phacoemulsification system utilizing feedback based IOP target control. ASCRS Presentation. 2014.
  4. Solomon K, Lorente R, Cionni R, Fanney D. Prospective, randomized clinical study using a new phaco system with intraocular system target pressure control. ASCRS-ASOA Symposium and Congress; April 25-29, 2014; Boston, USA.

Video Resources

View Case, testimonial and product videos

VIEW IMPORTANT PRODUCT INFORMATION FOR:

CENTURION® VISION SYSTEM IMPORTANT PRODUCT INFORMATION

CAUTION: Federal (USA) law restricts this device to sale by, or on the order of, a physician.

As part of a properly maintained surgical environment, it is recommended that a backup IOL Injector be made available in the event the AutoSert® IOL Injector Handpiece does not perform as expected.

INDICATION: The Centurion® Vision System is indicated for emulsification, separation, irrigation, and aspiration of cataracts, residual cortical material and lens epithelial cells, vitreous aspiration and cutting associated with anterior vitrectomy, bipolar coagulation, and intraocular lens injection. The AutoSert® IOL Injector Handpiece is intended to deliver qualified AcrySof® intraocular lenses into the eye following cataract removal.

The AutoSert® IOL Injector Handpiece achieves the functionality of injection of intraocular lenses. The AutoSert® IOL Injector Handpiece is indicated for use with the AcrySof® lenses SN6OWF, SN6AD1, SN6AT3 through SN6AT9, as well as approved AcrySof® lenses that are specifically indicated for use with this inserter, as indicated in the approved labeling of those lenses.

WARNINGS: Appropriate use of Centurion® Vision System parameters and accessories is important for successful procedures. Use of low vacuum limits, low flow rates, low bottle heights, high power settings, extended power usage, power usage during occlusion conditions (beeping tones), failure to sufficiently aspirate viscoelastic prior to using power, excessively tight incisions, and combinations of the above actions may result in significant temperature increases at incision site and inside the eye, and lead to severe thermal eye tissue damage.

Good clinical practice dictates the testing for adequate irrigation and aspiration flow prior to entering the eye. Ensure that tubings are not occluded or pinched during any phase of operation.

The consumables used in conjunction with ALCON® instrument products constitute a complete surgical system. Use of consumables and handpieces other than those manufactured by Alcon may affect system performance and create potential hazards.

AEs/COMPLICATIONS: Inadvertent actuation of Prime or Tune while a handpiece is in the eye can create a hazardous condition that may result in patient injury. During any ultrasonic procedure, metal particles may result from inadvertent touching of the ultrasonic tip with a second instrument. Another potential source of metal particles resulting from any ultrasonic handpiece may be the result of ultrasonic energy causing micro abrasion of the ultrasonic tip.

ATTENTION: Refer to the Directions for Use and Operator’s Manual for a complete listing of indications, warnings, cautions and notes.